Key Features and Functions
1. Protection Functions:
- Overvoltage & Undervoltage Protection: Automatically disconnects in case of voltage fluctuations, protecting sensitive equipment.
- Phase Loss Protection: Detects phase failure and ensures system safety.
- Overload Protection: Provides time-delay protection for circuits experiencing prolonged overloads.
- Short-Circuit Protection: Includes both short-time and instantaneous protection for fault conditions.
- Overheat Protection: Prevents damage by monitoring excessive temperatures within the breaker.
- Three-Phase Current Imbalance Protection: Safeguards against damage caused by current imbalances in three-phase systems.
2. Display Functions:
- OLED Display Screen: The 128x64 dot matrix OLED screen shows real-time data on voltage, current, power, temperature, energy usage, and faults.
- Automatic Display Cycle: Displays the current system status, cycling through key parameters for continuous monitoring.
- Fault Alarm: Immediate on-screen alerts for faults like overvoltage, undervoltage, and overheating.
3. Settings and Query Functions:
- Customizable Protection Settings: Users can adjust parameters like overvoltage, undervoltage, phase loss, overload delays, and short-circuit thresholds.
- User-Friendly Interface: Easily enable/disable settings via control buttons, making it adaptable to various operational needs.
- Parameter Query: Users can query current settings and historical data for system insights.
4. Control Features:
- Remote Control: Supports remote monitoring and parameter adjustments through its communication interface.
- External Panel Control: Offers flexibility with remote operation via an external panel.
- Synchronized Trip Function: Enables synchronized tripping when connected to other devices, ensuring coordinated protection.
5. Monitoring and Recording:
- Fault and Operation Logs: Tracks the number of fault-related trips and on/off cycles, helping evaluate product performance.
- Event Logging: Records and categorizes faults, simplifying analysis of operational history.
6. Auxiliary Features:
- MODBUS Protocol Support: Compatible with industrial automation systems for easy integration.
- Communication Modules: External modules enable remote data transmission and monitoring via cloud platforms.
- Remote Data Storage: Data is stored on the cloud for up to 90 days, allowing convenient access via mobile apps.
Working Conditions
- Operating Temperature: Functions effectively between -5°C to +55°C; ensure the environment stays within this range.
- Humidity: Maximum 90% relative humidity during the wettest month, with a minimum temperature of 25°C to avoid condensation.
- Altitude: Suitable for use up to 2000 meters; consult the manufacturer for higher altitudes.
- Pollution Level: Rated for level 3 pollution, common in industrial and commercial settings.
- Magnetic Field: External magnetic field should not exceed five times Earth's natural magnetic field to avoid interference with operation.
Communication Methods
- RS485 Communication: The circuit breaker features an RS485 communication port for connecting to other devices, allowing for integration into larger automation and control systems.
- Ethernet Communication: The breaker can be connected to an Ethernet network via an external communication module, enabling easier data transmission and remote monitoring.
- Mobile Monitoring via App: With built-in wireless communication, the breaker supports remote monitoring through a mobile app, allowing users to track performance and make adjustments from anywhere.
- Cloud Connectivity: Data can be transmitted wirelessly to a cloud platform, where it is stored and accessible for up to 90 days without the need for additional server infrastructure.